APC AP7922B Drag to turn · 3 views
APCPower Distribution Units (PDUs)

Rack PDU, Switched, 2U, 32A, 230V, (16)C13

Part # AP7922BUPC 731304331636Warranty: 2 years repair or replace14.4 lb

  • Single-phase Metered, Switched 2U Black
  • 16 AC outlet(s) C13 coupler
  • 7360 W
Special orderPrice on request
View quote list
  • Reply within 1 business day
  • Volume & business pricing
  • Shipping across Canada & US

Overview

Availability

01

Power Delays

Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

02

Load indicator LED

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

03

Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

04

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

05

Remote Individual Outlet Control

Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

06

Network Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

07

Local Current Monitoring Display

The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

08

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Marketing Features

09

Power Delays

Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

10

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

11

Remote Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

12

Remote Individual Outlet Control

Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

13

Local Current Monitoring Display

The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

14

Agility

15

Single input power source

Specifications

Design

PDU types
Metered, Switched
Type
Single-phase
Rack capacity
2U
Mounting
Horizontal
Product colour
Black

Ports & interfaces

AC outlets quantity
16 AC outlet(s)
Power plug
IEC309
AC outlet types
C13 coupler

Features

Cable length
3.05 m

Management features

Monitoring
Current, Power, Voltage
Outlet control
Lock-out, Recycle, Turn off, Turn on

Power

Nominal input voltage
200-230 V
AC input frequency
50 - 60 Hz
Maximum current
32 A
Nominal output voltage
230 V
Load capacity
7360 VA
Maximum input current per phase
32 A
Maximum total current draw per phase
32 A
Maximum power
7360 W

Certificates

Compliance certificates
RoHS
Certification
CE, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, REACH

Operational conditions

Operating temperature (T-T)
0 - 45 °C
Storage temperature (T-T)
-25 - 65 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m

Weight & dimensions

Width
445 mm
Depth
114 mm
Height
89 mm
Weight
4.5 kg

Packaging content

Packaging content
Documentation CD, Installation Guide, Rack Mounting Brackets

Packaging data

Package weight
6.55 kg
Package width
508 mm
Package depth
368 mm
Package height
140 mm