Maintenance Bypass PDU
- Reply within 1 business day
- Volume & business pricing
- Shipping across Canada & US
Overview
The CyberPower MBP15A6, a 6-outlet (rear), 1U Maintenance Bypass Power Distribution Unit (MBP PDU), provides 100-120 VAC 15A output (derated to 12A) to 6 NEMA 5-15R receptacles. Designed for datacenters and other electrically demanding applications, the MBP15A6 allows the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of the connected equipment when performing maintenance, replacing batteries, or installing a new UPS.
A 6-foot AC cord connects to utility power; a 3.3-foot AC cord connects to the output power of the UPS. The UPS draws input power from the MBP15A6 through a dedicated NEMA 5-15R separate from the outlets for connected devices. When the switch on the front of the MBP15A6 is turned from Normal to Bypass, or from Bypass to Normal, the power that the MBP supplies to connected devices moves from one input power source to another. The LED display indicates which power source is active.
Rugged, industrial-grade metal housing protects the MBP15A6. With a 1U form factor, this PDU can be mounted in a standard server rack. Its mounting hardware also enables it to be connected to a UPS for tower configurations. The MBP15A6 is UL and RoHS compliant. A three-year limited warranty covers the PDU for three years and connected equipment for as long as you own the product.
Power Distribution
Delivers AC power to servers, equipment, and connected devices via a power distribution unit.
Maintenance Bypass
Qualified personnel can use the bypass feature to disconnect the PDU from the UPS without disrupting power to connected equipment. This feature allows connected equipment to operate seamlessly during maintenance periods, battery replacement, or UPS installation.
Manual Bypass Switch
When the Manual Bypass Switch is turned to Normal, connected equipment is supplied by UPS output. When the Manual Bypass Switch is turned to Bypass, connected equipment is supplied by utility power.
Network-Grade Plugs and Outlets
Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.
1U Form Factor & Mounting Hardware
The 1U form factor is made to be mounted in a standard server rack. Mounting hardware allows the PDU to be connected to a UPS for tower configurations.
Durable Metal Housing
Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.
Three-Year Limited Warranty
Covers defects in materials and workmanship in the product under normal use and conditions. See warranty for details.
Specifications
Design
- Rack capacity
- 1U
- Housing material
- Steel
- Product colour
- Black
Ports & interfaces
- AC outlets quantity
- 6 AC outlet(s)
- Power plug
- NEMA L5-15P
- AC outlet types
- NEMA 5–15R
Features
- Cable length
- 1.82 m
Power
- Nominal input voltage
- 100-125 V
- Maximum current
- 15 A
- Nominal output voltage
- 120 V
Certificates
- Compliance certificates
- RoHS
- Certification
- UL60950_1, cUL
Operational conditions
- Operating temperature (T-T)
- 0 - 40 °C
- Operating relative humidity (H-H)
- 0 - 90%
Weight & dimensions
- Width
- 431.8 mm
- Depth
- 76.2 mm
- Height
- 50.8 mm
- Weight
- 1.6 kg
Downloads
More in PDUs & Line Conditioners
CyberPowerCPS Rackmount PDU 15ACPS1215RM
CyberPower125V/1800J 515R, 6ft cordCPS815RMS
CyberPowerSurge 4 Outlets 6 FT Cord 2 USB AP406U
CyberPower20A Derated to 16A, 208 230 V, 50Hz/60Hz, IEC320 C20 plug, 8 IEC320 C1PDU20BHVIEC8R
CyberPowerSwitched PDU 20A 120V NEMA L520P input 8 NEMA 520R output 12ft cord 1UPDU41002
CyberPower750VA/750W, Pure Sine Wave, NEMA 515P, 5 ft cord, 6 NEMA 515R, USB, SePR750LCD3C
CyberPowerCyberpower UPS Preplacement Battery, 2 X 6V/8AH Batteries, 18MONTH WTYRB0690X2A
CyberPowerReplacement Battery 12x12V/6AHRB1260X12